Rotary P.B. Union

(Sizes 1/2" to 1")

 

  

Installation Procedures

 

• A suitable run-in period before fitting is recommended. Rotate the P.B. at 300 r.p.m. for 15 minutes.

• Add system liquid if seals squeak.

• A torque arrestor may be fitted, but this must not restrict the rotary union.

• Ensure that the spindle thread is RH or LH to suit the direction of rotation of the machine shaft.

• If the machine shaft reverses direction of rotation, securely lock the spindle or (preferably) use a flanged connection.

• DO NOT fix valves etc. directly on to the rotary union.

• DO NOT connect with rigid pipe.

• DO NOT clamp the rotary union.  

 

 

 

 

Maximum Length For Flexible Hose

 

NOMINAL
SIZE

LENGTH (mm)

PART NUMBER

8 (1/4")

150 M.240/1

15 (1/2")

305 M.240/3

20 (3/4")

305 M.240/4

  

 

Next Page. . .

 

Back to Models Page           Back to Filton® Home Page

Other P.B. Links

• Description & Dimensions

• Model Numbers

• Part Identification

• Maximum Operating Recommendations

• Flow Capacity

• Installation Procedures

• Maintenance and Overhaul

• Lubrication

• Download P.B. Union Manual.pdf

 

Other Filton® Links

 Home

Filton® Main Menu

Intro to Rotary Unions

Typical Applications

Rotary Union Models

•  R.E. (1/4" to 1-1/4")

•  P.B. (1/2" to 1)"

•  C.B. (1/4" to 1-1/4")
High Temperature

•  R.E.B. (1-1/2" to 6")

•  C.B.N. (1-1/2" to 6")
High Temperature)

Other Models

Special Models

Special Connections

•  Screw Threads

•  Flanges

Accessories

•  Syphon Elbows

•  Flexible Hoses

Also Available from Filton®

Quick Selection Guide

Part Numbers & Cross References

About Filton Ltd.

Health and Safety