Filton® Rotary R.E. Union
(Sizes 1/4" to 1-1/4")
Installation Procedures
- A suitable run-in period before fitting is recommended. Rotate the R.E. at 300 r.p.m. for 15 minutes.
 - Add system liquid if seals squeak.
 - A torque arrestor may be fitted, but this must not restrict the rotary union.
 - Ensure that the spindle thread is RH or LH to suit the direction of rotation of the machine shaft.
 - If the machine shaft reverses direction of rotation, securely lock the spindle or (preferably) use a flanged connection.
 - DO NOT fix valves etc. directly on to the rotary union.
 - DO NOT connect with rigid pipe.
 - DO NOT clamp the rotary union.
 
					
	Maximum Length For Flexible Hose
	| Nominal Size | LENGTH (mm) | PART NUMBER | 
|---|---|---|
| 8 (1/4") | 150 | M.240/1 | 
| 10 (3/8") | 230 | M.240/2 | 
| 15 (1/2") | 305 | M.240/3 | 
| 20 (3/4") | 305 | M.240/4 | 
| 25 (1") | 380 | M.240/5 | 
| 32 (1-1/4") | 460 | M.240/6 |